Related Experiment Videos
The relationship between the vas volume and the anatomic size of the vas deferens
Abstract:
The anatomic sizes of 210 vas segments from 107 volunteers of vasectomy were measured by computerized image graphic technique with microphotography. The mean equivalent-round, outer and inner diameters of the vas were 2.17 +/- 0.20 mm and 0.56 +/- 0.08 mm, respectively. The calculated thickness of vas wall was 0.81 +/- 0.21 mm. The maximal volumes of 124 vas segments (1 cm in length) were tested by injecting colored solution into vas lumen until vas rupture. The mean rupture volume of 1 cm vas lumen was 0.05 +/- 0.007 mL. A significant influence of the thickness of vas wall (p < 0.05) and body height (p < 0.05) on the rupture volume was noticed in stepwise regression analysis. A tunnel-like rupturing pattern was observed in morphological observation. The obtained rupture volume provides a security line in determining the injection volume of occlusive material or the size of the implanted contraceptive device.