Related Experiment Video
Updated: Aug 13, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Change in oxygen enhancement ratio with depth in tissue-equivalent material for a collimated beam of fast neutrons
Abstract:
Survival of reproductive capacity of murine leukaemia P-388 cells was assayed in vivo after the cells had been irradiated in vitro under aerobic or hypoxic conditions with collimated beams of X rays or 16 MeV D-Be fast neutrons at various depths in tissue-equivalent phantom material. The response to X-irradiation was the same in the absence of the phantom and at 8-7 cm depth. The response to fast neutrons under aerobic conditions was unchanged from 0 to 23 cm depth within the phantom. However, under hypoxic conditions, the dose-response curve for fast neutrons became significantly steeper with increasing depth in the phantom. The OER decreased from 2-0 in the absence of the phantom to 1-5 at 15 cm deep.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
10:10Neutron Crystallography Data Collection and Processing for Modelling Hydrogen Atoms in Protein Structures
Published on: December 1, 2020
Related Concept Videos
Nuclear Transmutation
Biological Effects of Radiation
Nuclear Overhauser Enhancement (NOE)