Related Experiment Video
Updated: Sep 13, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Comparison of pulmonary gas exchange measurements between incremental and constant work exercise above the anaerobic
R J Zeballos1, I M Weisman, S M Connery
1Department of Clinical Investigation, William Beaumont Army Medical Center, El Paso 79920-5001, USA. zeballos@flash.net
Study Objectives:
To compare arterial blood gas (ABG) and pulmonary gas exchange variables (alveolar-arterial oxygen pressure difference [P(A-a)O2] and physiologic dead space to tidal volume ratio [VD/VT]) measured during incremental exercise test (IET) and constant work (CW) exercise at a matched oxygen uptake (VO2).
Design:
A comparison of IET and CW variables was accomplished using patient data from clinical referrals for cardiopulmonary exercise testing and control data not reported from a previous study.
Settings:
El Paso, Tex, located at an altitude of 1,270 m (barometric pressure, 656 mm Hg).
Participants:
Sixteen patients with dyspnea on exertion/exercise intolerance and nine normal subjects were evaluated above the anaerobic threshold (AT); seven patients were also studied below the AT.
Interventions:
Participants had a maximal IET followed in 1 h by a 5-min CW test. Arterial blood samples were obtained from a radial catheter every other minute during IET and during minute 5 of CW. Cardiopulmonary measurements were obtained using an automated system in a breath-by-breath fashion (60-s averaging).
Results:
Above the AT, no differences were observed in normal subjects between IET and CW at a matched VO2 in the following: PaO2 (79 vs 79 mm Hg); arterial oxygen saturation (SaO2) (94% vs 94%); P(A-a)O2 (16 vs 16 mm Hg); and VD/VT (0.09 vs 0.09) (mean values). Similarly, no differences were observed in patients above the AT in PaO2 (69 vs 68), SaO2 (90 vs 90), and VD/VT (0.24 vs 0.23). PaCO2 was 2 mm Hg higher (36 vs 34) in normal subjects and in patients (34 vs 32) during IET. A significant (p<0.05), albeit clinically unimportant, difference was also observed in P(A-a)O2 (28 vs 29) in patients. No statistically significant differences were observed below the AT between IET and CW for any of the variables measured.
Conclusions:
These data demonstrate the reliability of ABG and pulmonary gas exchange variables measured during 1-min IET for clinical use in patients and normal subjects. However, PaCO2 tends to be slightly higher during IET vs CW.
More Related Videos
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Volumes and Capacities