Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes
M A McCrory1, P A Molé, T D Gomez
1Departments of Nutrition and Exercise Science, University of California, Davis, California 95616-8669, USA. mccrory_em@hnrc.tufts.edu
Abstract:
The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle's law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD POD provides the use of a predicted Vtg (Vtgpred). The validity of using Vtgpred in place of measured Vtg (Vtgmeas) to determine the percentage of body fat (%BF) was evaluated in 50 subjects (36 women, 14 men; ages 18-56 yr). There was no significant difference between Vtgmeas and Vtgpred (mean difference +/- SE, 53.5 +/- 63.3 ml) nor in %BF by using Vtgmeas vs. Vtgpred (0.2 +/- 0.2 %BF). On an individual basis, %BF measured by using Vtgmeas vs. Vtgpred differed within +/-2.0% BF for 82% of the subjects; maximum differences were -2.9 to +3.0% BF. For comparison, data from 24 subjects who had undergone hydrostatic weighing were evaluated for the validity of using predicted vs. measured residual lung volume (VRpred vs. VRmeas, respectively). Differences between VRmeas and VRpred and in %BF calculated by using VRmeas vs. VRpred were significant (187 +/- 46 ml and 1.4 +/- 0.3% BF, respectively; P < 0.001). On an individual basis, %BF determined by using VRmeas vs. VRpred differed within +/-2.0% BF for 46% of the subjects; maximum differences were -2.9 to +3.8% BF. With respect to %BF measured by air displacement, our findings support the use of Vtgpred for group mean comparisons and for purposes such as screening in young to middle-aged individuals. This contrasts with the use of VRpred in hydrostatic weighing, which leads to significant errors in the estimation of %BF. Furthermore, although the use of Vtgpred has some application, determining Vtgmeas is relatively simple in most cases. Therefore, we recommend that the use of Vtgmeas remain as standard experimental and clinical practice.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Respiratory Volumes and Capacities
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...