Quantification of fluoxetine and norfluoxetine serum levels by reversed-phase high-performance liquid chromatography
J W Holladay1, M J Dewey, S D Yoo
1College of Pharmacy, Nursing and Allied Health Sciences, Division of Pharmacy, Howard University, Washington, DC 20059, USA.
Abstract:
A rapid and sensitive high-performance liquid chromatography assay method was developed to determine serum fluoxetine and norfluoxetine levels by single extraction of 0.1 ml of serum with sodium hydroxide. The mobile phase (55% acetonitrile-45% distilled water containing 10 mM aqueous triethylamine) was used to separate fluoxetine and norfluoxetine (25-1000 ng/ml, using clomipramine as the internal standard) by ultraviolet detection at 226 nm. The inter- and intra-day variabilities of fluoxetine and norfluoxetine were 13-18%, and the recoveries of both drugs exceeded 89%. This assay method was applied to a pharmacokinetic disposition study of fluoxetine in mice.