Related Experiment Video
Updated: Jan 9, 2026

An Improved Method for Collection of Cerebrospinal Fluid from Anesthetized Mice
Published on: March 19, 2018
The value of the coefficient of variation in assessing repeat variation in ECG measurements
S C McLaughlin1, T C Aitchison, P W Macfarlane
1Department of Medical Cardiology, University of Glasgow, Scotland, U.K.
Aims:
The coefficient of variation is a popular measure for describing the amount of repeat variability present in ECG measurements from recording to recording. However, it can be misleading. The aim of the present study was to assess repeat variation (reclassification) in computer measured ECG criteria, i.e. positive to negative or vice versa, and compare this with the coefficient of variability.
Methods And Results:
Two ECGs were obtained from each of 295 patients, one day apart, and separately from a further 364 patients, several minutes apart. All patients were considered to be in a stable condition. Estimates of the coefficients of variation were obtained for a number of ECG parameters used in the diagnosis of left ventricular hypertrophy. Corresponding reclassification rates of relevant ECG criteria were also calculated. Large coefficients of variation were observed in voltage parameters, e.g. R in V5 (20% for day-to-day recordings and 6% for minute-to-minute recordings) while the corresponding reclassification rates were 8% and 0% respectively. The repeat variation in the diagnosis of left ventricular hypertrophy was up to 5% for day-to-day recordings and up to 3% for minute-to-minute recordings based on several different criteria.
Conclusion:
A large coefficient of variation in a particular variable does not necessarily correspond to a high reclassification rate. A better measure of the impact of ECG variability for a particular measurement is obtained from its reclassification rate. In turn, this may have a minimal effect on the overall diagnosis of a particular abnormality.
Related Concept Videos
06:40An Improved Method for Collection of Cerebrospinal Fluid from Anesthetized Mice
08:40Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure
11:47Treating SCA1 Mice with Water-Soluble Compounds to Non-Specifically Boost Mitochondrial Function
05:51Intracerebroventricular and Intravascular Injection of Viral Particles and Fluorescent Microbeads into the Neonatal Brain
11:56A Rapid and Specific Microplate Assay for the Determination of Intra- and Extracellular Ascorbate in Cultured Cells
14:55Direct Intraventricular Delivery of Drugs to the Rodent Central Nervous System

