Related Experiment Video
Updated: Jul 13, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Lag-screw technique in free osseous mandibular reconstruction
P J Capizzi1, W M Jacobsen, N B Meland
1Division of Plastic and Reconstructive Surgery, Mayo Clinic Scottsdale, Arizona 85259, USA.
Abstract:
The surgical registry was reviewed for mandibular reconstruction from 1988 to 1992. During this time, 51 patients underwent mandibular reconstruction. Of this group, 17 patients had their microvascular bone grafts secured with lag-screw fixation. An AO technique, utilizing 2.7-mm cortical screws, was used to provide rigid fixation. Mandibular defects ranged from 6 to 20 cm. AO vascularized bone grafts were studied with bone scans and remained viable. Follow-up revealed no flap losses or oral cutaneous fistulae. Lag-screw fixation, in conjunction with mandibular reconstruction, results in rigid fixation, obviates the need for mandibulamaxillary fixation, has the advantage of ease of application, and is safe to use.