Related Experiment Video
Updated: Sep 11, 2026

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
[The difference between clinical ambulatory measured blood pressure and daily monitored pressure does not reflect the
C Santucciu1, G Parati, L Ulian
1Centro di Fisiologia Clinica e Ipertensione, Ospedale Maggiore, Milano.
Abstract:
The difference between clinic and average daytime ambulatory blood pressure is frequently used to identify patients with "white coat" hypertension (i.e. with a pronounced pressor response to the clinical evaluation) although there is no evidence that this difference is indeed due to a white coat effect. In 28 mild hypertensive outpatients, the blood pressure was continuously recorded by a noninvasive finger device before and during the doctor's visit. The peak blood pressure increase, recorded during the visit was compared with the difference between clinic and daytime average ambulatory blood pressure. Peak increases in systolic and diastolic finger blood pressure during the doctor's visit were 38.2 +/- 3.1 mmHg and 20.7 +/- 1.6 mmHg, respectively compared to pre visit values (means +/- standard error, both p < 0.01). Daytime average systolic and diastolic blood pressure were 135.5 +/- 2.5 mmHg and 89.2 +/- 1.9 mmHg, both being lower than the corresponding clinic blood pressure values (146.6 +/- 3.6 mmHg and 94.9 +/- 2.2 mmHg, p < 0.01). Their differences, however, were < 30% of the peak finger blood pressure increase during the physician's visit. While the physician's visit was associated with tachycardia (+9.0 +/- 1.6 b/min, p < 0.01) there was no difference between clinic and daytime average heart rate. The alerting reaction and the pressor response induced by the physician's visit is not reflected by the difference between clinic and daytime average blood pressure. Such a difference is not therefore a reliable measure of the white coat effect.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure