Related Experiment Video
Updated: Aug 10, 2026

Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses
Published on: January 23, 2017
The effect of white and filtered noise on contrast detection thresholds
1Environmental Research Institute of Michigan, Arlington, VA 22209, USA. avrama@gmu.edu
Abstract:
Models of the dipper effect seen in contrast discrimination experiments predict that small amounts of noise should facilitate detection of a subthreshold sinusoidal grating. Although facilitation of chromatic sine waves has been measured with chromatic or luminance noise, a facilitory effect of luminance sinusoidal gratings has not been measured, most likely because the stimulus characteristics were not tuned for revealing facilitation. The present study measures contrast detection thresholds (CDTs) of sinusoidal gratings in two-dimensional, static, band-limited white noise and low-pass and high-pass filtered noise using a two-interval forced-choice paradigm. The results show facilitation in near threshold white noise of middle frequency sinusoidal gratings, and facilitation in filtered noise of sinusoidal gratings whose frequency is far outside the pass band of the noise. Based on these results, a model of contrast detection thresholds is modified such that the facilitation is attributed to reduced observer uncertainty caused by small amounts of noise.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Sensation
Absolute thresholds can quantify the sensitivity of sensory...

