Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation
Related Experiment Video
Updated: Oct 30, 2026

A Novel Application of Musculoskeletal Ultrasound Imaging
Published on: September 17, 2013
P J Fish1, P R Hoskins, C Moran
1School of Electronic Engineering Science, University of Wales, Bangor, UK.
Abstract:
One of the major contributions to the improvement of spectral Doppler and colour flow imaging instruments has been the development of advanced signal-processing techniques made possible by increasing computing power. Model-based or parametric spectral estimators, time-frequency transforms, station-arising algorithms and spectral width correction techniques have been investigated as possible improvements on the FFT-based estimators currently used for real-time spectral estimation of Doppler signals. In colour flow imaging some improvement on velocity estimation accuracy has been achieved by the use of new algorithms but at the expense of increased computational complexity compared with the conventional autocorrelation method. Polynomial filters have been demonstrated to have some advantages over IIR filters for stationary echo cancellation. Several methods of velocity vector estimation to overcome the problem of angle dependence have been studied, including 2D feature tracking, two and three beam approaches and the use of spectral width in addition to mean frequency. 3D data acquisition and display and Doppler power imaging have also been investigated. The use of harmonic imaging, using the second harmonic generated by encapsulated bubble contrast media, seems promising particularly for imaging slow flow. Parallel image data acquisition using non-sequential scanning or broad beam transmission, followed by simultaneous reception along a number of beams, has been studied to speed up 'real-time' imaging.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...