[Optimal x-ray contrast media for ambulatory coronary angiography from the microcirculatory point of view]
Problem:
Side effects must be expected in 7 to 8% of cases, even when non-ionic radiocontrast agents are used. Contrast agent-induced microcirculatory disturbances constitute one potential cause under discussion. These disturbances may be caused by either the hyperviscosity or the hyperosmolality of the contrast agents. Within the framework of 3 comparative studies, the influence of viscosity and/or osmolality in intraarterial bolus injections on downstream microcirculation was tested in patients with coronary heart disease. Blood flow in the nailfold capillaries was recorded by intravital videomicroscopy and evaluated off-line, before and after randomized injection of 20 ml of each different radiocontrast agent into the Arteria auxillaries ipsilateral. Injection of 20 ml of a radiographic contrast agent into the Arteria auxillaries with a viscosity of 9.9 mPas and an osmolality of 770 mOsmol/kg H2O (Iopromid with 370 mg iodine/ml) results in a significant reduction in mean erythrocyte velocity in the ipsilateral nailfold capillaries from 0.76 +/- 0.27 to 0.39 +/- 0.31 mm/s after 30 s (p = 0.0001), corresponding to a reduction of 51.3%, whereas electrolyte solution shows no influence. With one exception, all patients reacted with a pronounced reduction in perfusion following injection of the radiocontrast agent, 3 patients showed an extreme reaction with flow cessation in the capillaries, in 1 case lasting up to 2 minutes. Following injection of 20 ml of Iodixanol with 270 mg iodine/ml (5.8 mPas, 290 mOsmol/kg H2O) a significant reduction of mean erythrocyte velocity of 60.8% was recorded from 0.44 +/- 0.27 mm/s to 0.17 +/- 0.09 mm/s only 10 s after the injection (p = 0.0001) lasting to the end of the observation period (6 minutes). Following injection of 20 ml of low-viscosity Iopentol with 150 mg iodine/ml and comparable osmolality (1.7 mPas, 340 mOsmol/kg H2O) no change in erythrocyte velocity was recorded (p = 0.151). Following injection of 2 high-viscosity radiocontrast agents of varying osmolality, mean erythrocyte velocity is reduced significantly in the first 30 s, after which period the erythrocyte velocity gradually increases (ANOVA repeated measures, category "time": p < 0.0001). The time curve for the 2 radiocontrast agents do not, however, differ (ANOVA, category "agents x time": p = 0.9890). Perfusion of the nailfold capillaries depends significantly on the viscosity, but not the osmolality, of the radiocontrast agent injected in coronary heart disease patients. From a microcirculatory point of view, it would therefore make sense to use low-viscosity radiocontrast agents in outpatients to exclude the existing risk of an induced myocardial microcirculatory disturbance.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies III: Computed Tomography