Application of a newly developed hydrogen peroxide vapor phase sensor to HPV sterilizer
I Taizo1, A Sinichi, K Kawamura
1Taiyo Toyo Sanso Co. Ltd., Saitama, Japan.
Abstract:
A new type of concentration sensor for hydrogen peroxide vapor has been developed by making use of a semiconductor. Output from the vapor sensor has been shown to have a good linear relationship with the logarithm of the concentration of hydrogen peroxide vapor. Concentration of hydrogen peroxide vapor introduced into the sterilization chamber could be kept constant by monitoring the concentration of the hydrogen peroxide vapor continuously and controlling the vapor supply. Temperature and humidity have also been kept constant. D-values for B. stearothermophilus ATCC 12980 at various concentrations of hydrogen peroxide vapor have been determined by using the combination system of the hydrogen peroxide vapor sensor, the hydrogen peroxide vapor supplier, thermosensor and humidity sensor. D-values at the temperature of 30 degrees C and the absolute humidity of 0.7 mg H2O/L thus obtained, were 0.2 minutes at hydrogen peroxide concentration of 600 ppm and 1.2 minutes at 200 ppm at the temperature of 30 degrees C and 0.7 mg/L absolute humidity. D-values for B. stearothermophilus ATCC 12980 at various temperatures, humidity and levels of hydrogen peroxide concentration have also been determined. These fundamental data indicate that the sterilization by hydrogen peroxide vapor can be validated as precisely as steam sterilization by measuring and controlling the concentration of hydrogen peroxide vapor using a combination of the hydrogen peroxide concentration sensor and the vapor generator. Influence of temperature and humidity have also been studied. The hydrogen peroxide sensor has been calibrated and standardized by using the standard hydrogen peroxide vapor whose concentration has been determined by calculating partial pressure of hydrogen peroxide over the water-hydrogen peroxide solution.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Gas Chromatography: Types of Detectors-II
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...