Related Experiment Video
Updated: Aug 18, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Effectiveness of mask ventilation in a training mannikin. A comparison between the Oxylator EM100 and the bag-valve
1Department of Emergency and Surgery, Kantonsspital, St. Gallen, Switzerland.
Abstract:
The demands for an optimal ventilation apparatus are that it can be easily handled, achieves a sufficiently high ventilation volume, and minimizes gastric inflation. Our aim was therefore to carry out a study in a training mannikin to find out whether the Oxylator EM100, compared with the bag, obtains improved ventilation and a decrease in gastric inflation. In a randomized crossover study, 72 subjects were selected (24 physicians, 44 nurses and 4 auxiliary nurses), chosen from the operating theatre, emergency department and intensive care unit of two hospitals. We used the Ambu-Bag Mark III with mask No. 4, the Oxylator EM100 with a pressure setting of 35 cm H2O run in the manual setting, the Ambu-Man C mannikin as well as the Ambu-CPR computer program. The resuscitation cycles of the standard two-rescuer's adult procedure lasted 3 min each, with a 3-min pause between the crossover procedure. The participants could improve their ventilatory volume with the Oxylator EM100 by 635 ml (95% confidence interval 578-692 ml) compared with the bag ventilation. The number of subjects who could attain a mean ventilatory volume of 800 ml or more increased from 15% to 98.6% (P < 0.001). Compared with the bag, the increase of adequate respirations (> or = 800 ml) obtained by the Oxylator EM100 for the individual participants amounted to a median of 91% (P < 0.001). Moreover, conventional ventilation caused in 42% one or several instances of gastric inflation, whereas no such reactions occurred with the Oxylator EM100. The Oxylator EM100 showed significantly better results in the mannikin than the bag. Of most importance is a significant lowering of gastric inflation and less so a marked increase in ventilatory volume. Our trial procedure with a relatively high lung compliance and a high oesophageal sphincter opening simulated favorable conditions. Owing to a large in vivo variability of these magnitudes, a direct testing in real patients with circulatory arrest is indicated.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiopulmonary Resuscitation II: ACLS Airway Management