Related Experiment Video
Updated: Aug 5, 2026

Implantation of Total Artificial Heart in Congenital Heart Disease
Published on: July 18, 2014
[The use of modified ultrafiltration in correcting complex congenital heart defects in newborn and nursing infants]
Abstract:
Modified ultrafiltration (MUF) was used in radical correction of complex congenital heart disease in 61 newborns and infants. The children were divided into 2 groups: group 1, 46 patients subjected to MUF, and group 2, 15 children operated on without MUF. Hemodynamic, hematological, biochemical, and immunological parameters were monitored. MUF in the newborns and infants helped adequately correct the hemohydrobalance due to ultrafiltration in the patient and hemoconcentration of the remaining volume in artificial ventilation device; it normalized the hematocrit values without additional infusion of donor blood. Elimination of inflammation mediators and cytokines recommends MUF for the treatment of newborns and infants.
More Related Videos
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Continuous Renal Replacement Therapy
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications