Related Experiment Videos
4- to 10-year results with the anatomic modular total knee
W D Bugbee1, D J Ammeen, N L Parks
1Department of Orthopaedics, University of California, San Diego, USA.
Clinical Orthopaedics and Related Research
|April 29, 1998
Summary
The Anatomic Modular Knee showed good results in total knee arthroplasty with low revision rates for loosening. Wear-related issues in polyethylene inserts were the main reason for reoperation in younger patients.
Area of Science:
- Orthopedic Surgery
- Biomaterials Engineering
Background:
- Total knee arthroplasty (TKA) is a common procedure for end-stage knee arthritis.
- The Anatomic Modular Knee is a specific implant design aiming to improve TKA outcomes.
- Long-term data on modular knee designs, particularly regarding polyethylene wear, is crucial.
Purpose of the Study:
- To report the intermediate-term outcomes of TKA using the Anatomic Modular Knee.
- To evaluate the revision rates and complication profiles of this specific implant.
- To identify factors contributing to reoperations, such as polyethylene wear.
Main Methods:
- Retrospective review of 186 consecutive Anatomic Modular Knee total knee arthroplasties.
- Follow-up data collected for 142 knees over 4 to 10 years (mean 6.9 years).
- Analysis of revision causes, implant survival, and complications, including polyethylene insert exchange.
Main Results:
- Two knees (1.4%) required revision of all components (infection, instability).
- Seven patients (4.9%) underwent modular tibial polyethylene insert exchange at a mean of 84 months.
- No aseptic loosening or patellofemoral complications were observed.
- Wear-related phenomena were the primary indication for reoperation, particularly in younger, active patients.
Conclusions:
- The Anatomic Modular Knee demonstrated favorable intermediate-term outcomes with a low rate of aseptic loosening and no patellofemoral issues.
- Wear of polyethylene inserts represents a significant concern, necessitating further investigation into modular insert design and isolated exchanges.
- This modular posterior cruciate-retaining design shows promise, but wear characteristics require additional study.