Objective:
To compare thermodilution right ventricular end-diastolic volume index (RVEDVI) and pulmonary artery occlusion pressure (Ppao) as predictors of the hemodynamic response to a fluid challenge.
Design:
Prospective cohort study.
Setting:
Medical ICU of a university-affiliated county hospital and medical-surgical ICU of a community hospital.
Patients:
Twenty-five critically ill patients who had one or more clinical conditions that suggested the possibility of inadequate preload.
Interventions:
Thirty-six fluid challenges. Fluid (saline or colloid) was administered rapidly until the Ppao rose by at least 3 mm Hg. When a patient underwent more than one fluid challenge, these were given on separate days and for different clinical indications.
Measurements And Results:
Responders (n=20; > or = 10% increase in stroke volume [SV]) and nonresponders (n=16; <10% increase in SV) differed with respect to baseline Ppao (10.0+/-3.4 vs 14.2+/-3.6 mm Hg; p=0.001), but not with respect to baseline RVEDVI (105+/-31 vs 119+/-33 mL/m2; p=0.22). There was a moderate correlation between RVEDVI and fluid-induced change in SV (r=0.44); the relationship between Ppao and change in SV was stronger (r=0.58). A positive response to fluid was observed in 4 of 9 cases in which RVEDVI exceeded 138 mL/m2, a threshold value that has been suggested to reliably predict a poor response to fluid.
Conclusion:
RVEDVI was not a reliable predictor of the response to fluid. As a predictor of fluid responsiveness, Ppao was superior to RVEDVI. In an individual patient, adequacy of preload is best assessed by an empiric fluid challenge.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Heart Failure II: Pathophysiology