Related Experiment Videos
The tension wire method: a simple, effective means of mandibular fixation
R C Wang1, D R Keech, T P Elkins
1Division of Otolaryngology-Head and Neck Surgery, Texas Tech University Health Sciences Center, Lubbock, USA.
Objective:
To investigate the use of a tension wire band secured to monocortical screws for open reduction and internal fixation of simple, displaced, and/or unstable mandibular fractures.
Design:
Retrospective review with follow-up duration of at least 6 weeks.
Setting:
Level I university trauma center.
Patients:
Twenty-nine patients (27 males and 2 females), aged 7 to 46 years. Ten patients had unilateral fractures (1 patient had 3 separate unilateral fractures) and 19 had bilateral fractures; 34 of 50 fractures were displaced; 19 were open intraorally. The location of fractures and the number (number repaired) were as follows: symphysis or parasymphysis, 13 (10); body, 9 (8); angle, 18 (14); ramus, 6 (4); and subcondylar, 4 (0). Two fractures were each comminuted into 3 fragments, and 1 patient had unilateral parasymphysial, body, and ramus fractures.
Intervention:
Intermaxillary fixation was done in all patients except 1 child. Intraoral approaches were used exclusively. A pair of monocortical 2.0-mm screws were placed perpendicular to fracture lines, with 24-gauge wire loops passed around the screws and tightened to bring the fracture into reduction and provide stable fixation. A percutaneous trocar system was used to insert screws at the body, angle, and ramus sites.
Results:
There were no instances of infection, malunion, or malocclusion in the 33 fractures repaired with this technique. A typical intermaxillary fixation with open reduction and internal fixation of a posterior fracture was done in less than 2 hours.
Conclusion:
Open reduction and internal fixation of simple mandibular fractures with tension wire bands around monocortical screws is a simple, quick, and effective technique.