Related Experiment Video
Updated: Aug 19, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Gas-liquid chromatography of nucleosides. Derivatization and chromatography
Abstract:
The aims of this investigation were to establish the optimum reaction conditions for silylation of nucleotides with bis(trimethylsilyl)trifluoroacetamide (BSTFA) and to investigate the chromatographic properties of the following nucleosides: adenosine, guanosine, cytidine, thymine, inosine, xanthosine, and uridine. Closed tube silylations were performed with a 1000 molar excess of BSTFA at 25, 75, 120, 150, and 175 degrees for 15, 30, 60, 120 and 240 min. The optimal time and temperature for derivatization were found to be 150 degrees and 15 min. Using these reaction conditions, samples were then silylated with 50, 100, 200, 500, and 1000 molar excess of BSTFA; a molar excess of 225 was best. The stability of the nucleoside derivatives on standing at room temperature for 1-7 days was investigated. Quantitative gas-liquid chromatography of trimethylsilyl (TMS) nucleosides can be performed if samples are analyzed within 48 h, after which time the relative weight response for the nucleosides decreased somewhat. Chromatographic column studies were made using various liquid phases and supports. With methylsiloxanes as the liquid phase, Supelcoport as support was found to be superior. Resolution of TMS guanosine from TMS cytidine was attempted at different column lengths using 3% (w/w) SE-30 on Supelcoport, different loadings (%, w/w) of SE-30 on Supelcoport, and different polarity liquid phases, 4% (w/w) OV-11 or 3% (w/w) OV-17 or 4% (w/w) Dexsil-300 on Supelcoport. A complete separation of the six ribonucleosides including guanosine and cytidine was obtained with 1 m x 4 mm I.D. glass columns of 4% (w/w) OV-11 and 3% (w/w) OV-17 on 100-120 mesh Supelcoport. It was observed that with 2'-deoxycytidine, one obtains the TMS cytosine peak (retention temperature 150 degrees) plus another peak with a retention temperature of 120 degrees, under all derivatization conditions with BSTFA and bis(trimethylsilyl)-acetamide. Similar formation of bases from other 2'-deoxyribonucleosides occurred when the molar excess of BSTFA was greater than 500. The minimal detectable amounts obtained for all the nucleosides ranged from 5 to 10 ng injected with a signal-to-noise ratio of 3. The relative standard deviations for all nucleosides and deoxynucleosides ranged from 1.2 to 4.8% on different methylsiloxanes on Supelcoport columns.
More Related Videos
06:38Plant Sample Preparation for Nucleoside/Nucleotide Content Measurement with An HPLC-MS/MS
Published on: February 24, 2021
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography