Iohexol plasma clearance in determining glomerular filtration rate in diabetic patients
Related Experiment Video
Updated: Oct 2, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
L Pucci1, S Bandinelli, G Penno
1Cattedra di Malattie Metaboliche e del Ricarubjo, Università degli Studi di Pisa, Italy.
Abstract:
The plasma clearance of iohexol has recently been proposed as a new method for estimating GFR. The iohexol plasma clearance was compared with that of 51Cr-EDTA in 32 diabetic patients (12 IDDM, 20 NIDDM; age 23-70; diabetes duration 1-35 years) with normal to impaired renal function (serum creatinine: 0.8-6.4 mg/dL). Bolus i.v. injection of 51Cr-EDTA (1 muCi/kg) was followed by 5 mL slow i.v. injection of Omnipaque (Nycomed, Oslo, Norway). Samples for radioactivity and iohexol analysis were drawn at 0, 5, 10, 15, 30, 60, 90, 120, 150, 180, 210, 240, 270, 300 min (+360 and 420 min if serum creatinine > 2.0; +1440 min if > 5.0 mg/dL). Iohexol was assayed in duplicate by HPLC throughout a Nova-Pak C18 column (Waters-Millipore, USA). Only the second peak obtained during elution of iohexol (about 4.5 min) was used for calculation. Dilution tests show highly linear regressions for concentrations between 3.25-650 micrograms/mL (r = 0.99). Imprecision of iohexol assay (the whole procedure from deproteinization to chromatography) was: intra-assay 1.4 +/- 1.5%, mlsd (95% CI: 1.0-1.8%); inter-assay 3.0 +/- 2.7% (1.4-4.6%). Iohexol plasma clearance ranged between 12.9 and 150.9 mL/min, while 51Cr-EDTA plasma clearance between 11.9 and 149.8 mL/min with excellent correlation (iohexol = 0.95 51Cr-EDTA + 2.49; r = O.995). Mean CV between the two methods was 1.7% (range 0-4.9%) with a significant negative correlation (r = 0.5 I, p = 0.007) with the GFR levels. Correlation between repeated measurements, performed in eight patients, was excellent (r = O.994, P = 0.0001). In diabetes, GFR measured by plasma clearance of iohexol shows an excellent agreement with plasma clearance of 51Cr-EDTA throughout a wide range of renal function. Iohexol provides an accurate alternative method for measuring GFR.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles.
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

