Related Experiment Video
Updated: Aug 18, 2026

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
High-volume aspiration as a supplemental scavenging method for reducing ambient nitrous oxide levels in the
1Department of Pediatric Dentistry, University of Texas, USA.
Abstract:
Occupational exposure to low levels of nitrous oxide (N2O) have been associated with adverse health effects. The National Institute for Occupational Safety and Health has established a threshold guideline of 25 ppm N2O. The purpose of this laboratory study was to determine the effectiveness of a high-volume dental aspirator as a supplemental device to reduce ambient N2O levels in the operatory. The investigation evaluated four experimental groups that were assigned based on whether or not the aspirator was used and on the rate at which operatory ventilation was established (5 or 10 room air exchanges per hour). Ambient N2O levels were monitored at 30 cm from the nasal hood using an infrared spectrophotometer. The room air exchange rate was measured with a flow hood and then manipulated to the desired ventilation rate. N2O levels were detected with a spectrophotometer and data were recorded with a microprocessor that continuously collected data. The results demonstrated that both utilization of supplemental oral aspiration and increased operatory ventilation significantly reduced ambient N2O levels. It was concluded that a high-volume aspirator, when used in conjunction with the normal scavenging system, can significantly reduce ambient N2O levels to within the guidelines established by the National Institute for Occupational Safety and Health.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Inhalational Anesthetics: Overview
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cardiopulmonary Resuscitation II: ACLS Airway Management