Related Experiment Videos
Fast MR imaging and the detection of small-bowel obstruction
F Regan1, D P Beall, M E Bohlman
1Department of Imaging, The Johns Hopkins Bayview Medical Center, Baltimore, MD 21224, USA.
Objective:
Our aim was to determine whether fast MR imaging using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) MR sequence is accurate for diagnosis of small-bowel obstruction.
Materials And Methods:
Forty-three nonconsecutive patients with suspected small-bowel obstruction were evaluated with HASTE MR imaging during a 12-month period. Images were retrospectively assessed for the presence, level, and cause of bowel obstruction. Data were compared with results of conventional radiography and findings at surgery when available.
Results:
Of the 43 patients imaged, 29 patients had small-bowel obstruction revealed by unenhanced or contrast-enhanced radiography or by CT. Surgical confirmation was available in 21 patients. Small-bowel obstruction was shown by HASTE MR imaging in 26 (90%) of these 29 patients. HASTE MR images showed the correct level of obstruction in 19 (73%) of the 26 patients and showed the cause of obstruction in 13 (50%) of the 26 patients.
Conclusion:
With a high degree of accuracy, HASTE MR imaging can show the presence and level of small-bowel obstruction.