Caudal epidurals: the whoosh test
D Eastwood1, C Williams, I Buchan
1Department of Anaesthetics, Arrowe Park Hospital, Upton, Wirral, Merseyside, UK.
Anaesthesia
|June 5, 1998
Summary
The whoosh test, an aid for caudal epidural injections, is more reliable than clinical judgment alone in confirming correct needle placement. This prospective study evaluated its effectiveness in ensuring accurate needle positioning during the procedure.
Area of Science:
- Anesthesiology
- Pain Management
- Minimally Invasive Procedures
Background:
- Caudal epidural injections are common procedures with low complication rates.
- Accurate needle placement is crucial for efficacy and safety.
- The whoosh test is a proposed method to verify correct needle placement in the caudal epidural space.
Purpose of the Study:
- To compare the diagnostic accuracy of the whoosh test versus clinical impression for correct caudal epidural needle placement.
- To evaluate the sensitivity and specificity of the whoosh test.
Main Methods:
- A prospective, 1-year study involving 131 patients undergoing caudal epidural injections.
- Fluoroscopic imaging was used as the gold standard to confirm needle position.
- The whoosh test and clinical impression were assessed for their accuracy.
Main Results:
- 92% of patients achieved correct needle placement on the first attempt.
- Clinical impression alone showed 94% sensitivity but only 20% specificity.
- The whoosh test demonstrated 80% sensitivity and 60% specificity.
Conclusions:
- The whoosh test is superior to clinical judgment alone in identifying incorrect needle placement during caudal epidural injections.
- The whoosh test can improve the safety and efficacy of caudal epidural procedures.