Evaluation of a cross-validation stopping rule in MLE SPECT reconstruction

C Falcón1, I Juvells, J Pavía

  • 1Laboratori de Biofísica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Spain.

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
Quantifying and Rejecting Outliers: The Grubbs Test01:02

Quantifying and Rejecting Outliers: The Grubbs Test

Sometimes, a data set can have a recorded numerical observation that greatly  deviates from the rest of the data. Assuming that the data is normally distributed, a statistical method called the Grubbs test can be used to determine whether the observation is truly an outlier.  To perform a two-tailed Grubbs test, first, calculate the absolute difference between the outlier and the mean. Then, calculate the ratio between this difference and the standard deviation of the sample. This number is...
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
Truncation in Survival Analysis01:09

Truncation in Survival Analysis

Truncation in survival analysis refers to the exclusion of individuals or events from the dataset based on specific criteria related to the time of the event. This exclusion can happen in two primary forms: left truncation and right truncation.
Left truncation occurs when individuals who experienced the event of interest before a certain time are not included in the study. This is often due to a "delayed entry" into the study where only those who survive until a certain entry point are observed.