Related Experiment Video
Updated: Aug 17, 2026

Guide Wire Assisted Catheterization and Colored Dye Injection for Vascular Mapping of Monochorionic Twin Placentas
Published on: September 5, 2011
Ante- and intrapartum diagnosis of vasa praevia in singleton pregnancies by colour coded Doppler sonography
1Department of Obstetrics and Gynaecology, Medical University of Lübeck, Germany.
Vasa praevia is a rare complication of pregnancy associated with a high fetal morbidity and mortality. As planned caesarean section can circumvent fetal risks, early detection of vasa praevia is desirable. Antenatal diagnosis by ultrasound by visualisation of vasa praevia may be difficult by transvaginal sonography alone due to an unfavourable angle of insonation. Combination of transabdominal and transvaginal sonography is superior in imaging the placental type, location, insertion of the cord and vasa praevia. We present four cases of antepartum and one case of intrapartum diagnosis of vasa praevia in singleton pregnancies using transabdominal and transvaginal colour coded Doppler sonography. A bipartite placenta with normal cord insertion was found in three cases and with velamentous insertion of the cord in one case. One case had a partially membranous placenta with velamentous insertion of the cord. From the site of cord insertion fetal vessels were coursing over the internal cervical os and then continued in an amniotic sheet to the main placental mass on the opposite uterine wall.
Vasa praevia is a rare complication of pregnancy associated with a high fetal morbidity and mortality. As planned caesarean section can circumvent fetal risks, early detection of vasa praevia is desirable. Antenatal diagnosis by ultrasound by visualisation of vasa praevia may be difficult by transvaginal sonography alone due to an unfavourable angle of insonation. Combination of transabdominal and transvaginal sonography is superior in imaging the placental type, location, insertion of the cord and vasa praevia. We present four cases of antepartum and one case of intrapartum diagnosis of vasa praevia in singleton pregnancies using transabdominal and transvaginal colour coded Doppler sonography. A bipartite placenta with normal cord insertion was found in three cases and with velamentous insertion of the cord in one case. One case had a partially membranous placenta with velamentous insertion of the cord. From the site of cord insertion fetal vessels were coursing over the internal cervical os and then continued in an amniotic sheet to the main placental mass on the opposite uterine wall.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies V: Intravenous Urography and Retrograde Pyelography

