Frequency analysis of human atrial fibrillation using the surface electrocardiogram and its response to ibutilide
Related Experiment Video
Updated: Oct 29, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
A Bollmann1, N K Kanuru, K K McTeague
1Section of Cardiac Electrophysiology, Cardiology Division, Emory University Hospital, Atlanta, Georgia 30322, USA.
Abstract:
This study assesses a technique for quantifying the frequency spectrum of atrial fibrillation (AF) using the surface electrocardiogram. Electrocardiograhic recordings were obtained in 61 patients during AF. After bandpass filtering, the QRST complexes were subtracted using a template-matching algorithm. The resulting fibrillatory baseline signal was subjected to Fourier transformation and displayed as a frequency power spectrum. These frequency spectra were compared to direct measurements from the right atrium and coronary sinus in 35 patients undergoing electrophysiologic study. The clinical use of this technique was explored by correlating fibrillatory frequency with the behavior of the arrhythmia in 26 patients referred for cardioversion. The electrocardiographic frequency spectrum during AF was characterized by a single peak that varied widely between patients (range 228 to 480 beats/min). There was a strong correlation between electrocardiographic peak frequency and that measured in the right atrium and coronary sinus (r = 0.79 to 0.98, p <0.0001). Episodes of AF that terminated in < 5 minutes had a lower frequency than those that persisted > 5 minutes (324 +/- 36 vs 402 +/- 78 beats/min, p = 0.001). Chronic AF (< 3 months in duration) had a lower frequency than chronic AF (present > 3 months) (336 +/- 48 vs 408 +/- 60 beats/ min, p = 0.012). Fibrillation frequency was an accurate predictor of conversion with ibutilide. Success rate was 100% in patients with peak frequency < 360 beats/min versus 29% in patients with frequencies > or = 360 beats/min (p = 0.003). Automatic analysis of the frequency content of the fibrillatory baseline on the surface electrocardiogram accurately reflects the average rate of AF. This measurement correlates with the clinical pattern of the arrhythmia and predicts the response to administration of ibutilide.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias