Related Experiment Video
Updated: Jul 16, 2026

Ex Vivo Red Blood Cell Hemolysis Assay for the Evaluation of pH-responsive Endosomolytic Agents for Cytosolic Delivery of Biomacromolecular Drugs
Published on: March 9, 2013
Sensitive enzymatic assay for erythrocyte creatine with production of methylene blue
1Department of Laboratory Medicine, Kochi Medical School, Nankoku, Japan. okumiyat/KMS@kochi-ms.ac.jp
Abstract:
We developed a new, highly sensitive enzymatic method for quantifying creatine in erythrocytes, which comprises creatine amidinohydrolase, sarcosine oxidase, and peroxidase. In the present method, an N-methylcarbamoyl derivative of methylene blue, 10-N-methylcarbamoyl-3,7-bis(dimethylamino)phenothiazine (MCDP), was used as a sensitive chromogenic compound. Potassium ferrocyanide was used to prevent nonspecific oxidation of MCDP. The enzymatic method exhibited good analytical performance: precision, within-run CVs <1.0% and between-day CVs <2.0%; average analytical recovery, 99.3% +/- 1.8%; detection limit, 1.0 micromol/L in hemolysate; and linearity, at least up to 500 micromol/L as creatine concentration in hemolysate. Excellent agreement was observed between the present method (y) and HPLC (x), y = 1.029x - 0.002 micromol/g hemoglobin, r = 0.9998, S(y/x) = 0.053 micromol/g hemoglobin (n = 110). No significant interference was produced by various compounds, including guanidino compounds, amino acids, and reducing materials. The reference intervals (mean +/- 2 SD) for erythrocyte creatine obtained from 60 males and 60 females were (in micromol/g hemoglobin) 1.18 +/- 0.52 (0.66-1.70) for males and 1.35 +/- 0.49 (0.86-1.84) for females. Using this method, we documented changes in erythrocyte creatine in patients with various hemolytic conditions, including hemolytic anemia, liver cirrhosis, renal insufficiency, and chronic renal failure treated with hemodialysis with or without the administration of erythropoietin. We conclude that the use of MCDP allows sensitive measurement of erythrocyte creatine and that MCDP with potassium ferrocyanide can improve the sensitivity of assays that use peroxidase for detection of H2O2.
More Related Videos
08:37Analyzing Supercomplexes of the Mitochondrial Electron Transport Chain with Native Electrophoresis, In-gel Assays, and Electroelution
Published on: June 1, 2017
09:16Real-Time Analysis of Bioenergetics in Primary Human Retinal Pigment Epithelial Cells Using High-Resolution Respirometry
Published on: February 3, 2023