Related Experiment Video
Updated: Aug 5, 2026

Assessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery (SALLI) MRI in Rats
Published on: July 19, 2013
Automatic assessment of cardiac function from short-axis MRI: procedure and clinical evaluation
E Nachtomy1, R Cooperstein, M Vaturi
1Center for Medical Physics, School of Physics and Astronomy, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Israel.
Abstract:
Cardiac magnetic resonance imaging (MRI) provides a wealth of morphological and physiological information. Automatic extraction of this information is possible by implementing various image processing techniques. However, existing procedures mostly rely on extensive human interaction and are seldom evaluated on a clinical scale. In this study, a nearly automatic process that extracts physiological parameters from cardiac MR images has been both developed and clinically evaluated. Raw images were obtained in the short-axis view and acquired by a gradient-cho (GE) protocol. In images selected to be analyzed, the only manual step required is the indication of a point in the center of the left ventricle (LV). From a set of such images, the process extracts endocardial and epicardial contours and calculates left ventricular volumes, mass and ejection fraction (EF). The process implements novel approaches to image processing techniques such as thresholding and shape extraction and can be adapted to other acquisition protocols. The process has demonstrated a clear potential for accurate extraction of the endocardial contour but a lower one with respect to the epicardial contour as a result of the low contrast between myocardium and some surrounding tissues, generated by the gradient-echo protocol. The ability of the process to asses physiological parameters has been subjected to a systematic clinical evaluation, which compared parameters, derived manually and automatically, in 10 healthy subjects and 10 patients. The evaluation has indicated that although individual volumes and mass were not accurately assessed, the automatic process has shown high potential for assessing the ejection fraction with relatively high accuracy and reliability.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Mitral Stenosis II: Clinical features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies