A self-tuning effect of membership functions in a fuzzy-logic-based cardiac pacing system
Related Experiment Video
Updated: Oct 29, 2026

Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine
Published on: February 17, 2018
T Sugiura1, N Sugiura, T Kazui
1Research Institute of Electronics, Shizuoka University, Hamamatsu, Japan.
Abstract:
This paper describes a self-tuning method of membership functions in a fuzzy-logic-based cardiac pacing system and validates its feasibility in a double sensor system which has minute ventilation and oxygen saturation level as its guides for the rate regulation. Though the agreement between the pacing rates (fuzzy rates) calculated with three linguistic variables for each parameter and the target rates were not satisfactory, it was improved significantly by tuning the membership functions. Almost the same evaluated values with those obtained by using six linguistic variables for each parameter were obtained. Time required for the self-tuning process was about 40 s (386CPU, 20 MHz) which was fast enough for the system. The smaller number of linguistic labels results in a smaller number of rules, which is beneficial in implantable cardiac pacemakers with limited memory capacity. A fuzzy-logic-based cardiac pacing system is promising for the realization of custom-made cardiac pacemakers.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires careful...
Root Loci for Positive-Feedback Systems
The construction rules for the root locus in positive feedback systems are similar to those in...
