Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast
K Wei1, A R Jayaweera, S Firoozan
1Cardiovascular Division, University of Virginia School of Medicine, Charlottesville 22908, USA.
Objectives:
This study sought to determine the basis of detection of stenosis by myocardial contrast echocardiography using venous administration of microbubbles and to define the relative merits of bolus injection versus continuous infusion.
Background:
The degree of video intensity (VI) disparity in myocardial beds supplied by stenosed and normal coronary arteries can be used to quantify stenosis severity after venous administration of microbubbles. However, the comparative merits of administering microbubbles as a bolus injection or continuous infusion has not been studied.
Methods:
Coronary stenoses of varying severity were created in either the left anterior descending or the left circumflex coronary artery in 18 dogs. Imagent US (AF0150) was given as a bolus injection in 10 dogs (Group I) and as both a bolus injection and a continuous infusion in 8 dogs (Group II). For bolus injections, peak VI was derived from time-intensity plots. During continuous infusion, microbubble velocity and microvascular cross-sectional area were derived from pulsing interval versus VI plots. Myocardial blood flow (MBF) was determined using radiolabeled microspheres.
Results:
During hyperemia, VI ratios from the stenosed versus normal beds correlated with radiolabeled microsphere-derived MBF ratios from those beds for both bolus injections (r = 0.81) and continuous infusion (r = 0.79). The basis for detection of stenosis common to both techniques was the decrease in myocardial blood volume distal to the stenosis during hyperemia. The advantage of continuous infusion over bolus injection was the abolition of posterior wall attenuation and the ability to quantify MBF.
Conclusions:
Both bolus injection and continuous infusion provide quantitative assessment of relative stenosis severity. Compared with bolus injection, continuous infusion also allows quantification of MBF and data acquisition without attenuation of any myocardial bed.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
06:46Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
Published on: July 16, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies