Related Experiment Video
Updated: Aug 19, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Assessment of pulmonary mechanics in mechanical ventilation: effects of imprecise breath detection, phase shift and
P A Stegmaier1, A Zollinger, J X Brunner
1Institute of Robotics, Swiss Federal Institute of Technology, Zurich. p.stegmaier@ieee.org
Objective:
In mechanical ventilation, the assessment of pulmonary mechanics, mainly of total compliance (Crs), total resistance (Rrs), and intrinsic positive end-expiratory pressure (PEEPint), is clinically important. By using airway pressure (Paw) and flow (V'aw), the least squares fit (LSF) method allows the continuous calculation of these parameters. The objective of this work was to study the influence of imprecise breath detection, phase shift between airway pressure and flow signals, and noise on the determination of Crs, Rrs, and PEEPint.
Methods:
Paw and V'aw were mathematically simulated as well as recorded in mechanically ventilated patients. Crs, Rrs, and PEEPint were computed off-line using the LSF method. The boundaries of the breath data window and the phase relationship between Paw and V'aw signals were manipulated and noise was superimposed.
Results:
Both simulated and patient data gave similar results. Crs and Rrs were not sensitive to imprecise breath detection. If the first portion of the breath was missed, the mean relative error on PEEPint was 20% or 53% when the exact beginning of inspiration was missed by 0.1 or 0.3 sec, respectively. Paw lag of 66 ms with respect to V'aw yielded a relative error of -15 +/- 4% (mean +/- SD) for Rrs, -5 +/- 2% for Crs, and +13 +/- 16% for PEEPint. Paw lead of 66 ms with respect to V'aw yielded a relative error of +5 +/- 4% for Rrs, +7 +/- 3% for Crs, and +14 +/- 18% for PEEPint. Noise had very little impact on the accuracy of Crs, Rrs, and PEEPint.
Conclusions:
We conclude that the LSF method allows the assessment of Crs, Rrs, and PEEPint even with high levels of noise in patients with normal lungs provided that Paw and V'aw signals are precisely synchronised and a reliable breath detection algorithm is used.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...