Related Experiment Video
Updated: Aug 9, 2026

Whole-animal Imaging and Flow Cytometric Techniques for Analysis of Antigen-specific CD8+ T Cell Responses after Nanoparticle Vaccination
Published on: April 29, 2015
Detection of antigen-specific T cell cytokine expression in whole blood by flow cytometry
M A Suni1, L J Picker, V C Maino
1Becton Dickinson Immunocytometry Systems, San Jose, CA 95131, USA. maria_suni@bdis.com
Abstract:
We have recently described a highly sensitive flow cytometric technique, based on the ability to detect single cell expression of cytokines, to simultaneously quantitate and phenotypically characterize antigen-specific memory/effector T cells in PBMC cultures. In this report, we describe a simplified procedural modification which enables the rapid detection of low frequency memory CD4+ and CD8+ T cells expressing cytokines in response to soluble antigen in whole blood. When compared with T cell responses in PBMC cultures, whole blood cultures demonstrated similar but slightly higher percentages of T cells responsive to specific antigen. In addition, T cell responses to cytomegalovirus in whole blood were observed only in sensitized (seropositive) individuals, and CD4+ T cell responses could be blocked by anti-class II MHC antibodies. This procedure may provide a means to examine direct effects of pharmacological drug concentrations on T cell immunity in clinical samples.