Related Experiment Video
Updated: Aug 11, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Prediction of arterial partial pressure of oxygen with pulse oxygen saturation measurements
1Department of Pediatrics, University of Colorado School of Medicine, Denver, Colorado 80262, USA.
Objectives:
We studied 22 neonates with gestational ages from 26 to 40 weeks to determine how accurately pulse oxygen saturation (SpO2) could predict arterial partial pressure of oxygen (PaO2) and how much time and effort would be required to achieve and maintain a desired SpO2 value.
Study Design:
SpO2 was maintained at 90%, 92%, 94%, 96%, and 98% by adjustment of FiO2. PaO2 was correlated with SpO2 by nonlinear mixed effects regression analysis.
Results:
PaO2(y) correlated positively with SpO2(x): y = (0.03). e0.08(x). Variation of PaO2 increased from a range of +/- 10 Torr at SpO2 = 90% to +/- 28 Torr at SpO2 = 98%, principally as a result of decreasing hemoglobin-oxygen affinity, with no effect of advancing gestational age, subject temperature, pH, PaCO2. Considerable time (18 +/- 14 SD minutes) and effort (5 +/- 3 SD FiO2 adjustments/min were required to achieve and maintain a desired SpO2.
Conclusions:
PaO2 varied broadly with SpO2 in a clinically acceptable range of SpO2 (90% to 98%), and the variability increased at higher SpO2 values. Considerable time and effort were required to achieve and maintain desired SpO2 values.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...