Related Experiment Video
Updated: Aug 1, 2026

Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
[Stenting in a recently implanted stent in a saphenous vein graft for optimizing angiographic results]
A Esteves Filho1, C K Takimura, E C Lira
1Instituto do Coração do Hospital das Clínicas, FMUSP.
Abstract:
A 60 year-old woman with progressive angina who had been submitted to saphenous bypass-graft to right coronary artery and a left mammary artery graft to anterior descending artery eight years previously, underwent implantation of a Gianturco Roubin II stent in the proximal third of the saphenous vein graft. The result was suboptimal by persistence of a residual stenosis probably due to prolapse of atherosclerotic material through the coil spaces. Another stent (Palmaz-Schatz biliar stent) was implanted at the previously stented site with no residual stenosis. Another Palmaz-Schatz biliar stent was successfully implanted in the distal body of the graft to treat another lesion (passing through the previously stents without difficulty). Stenting a stent, in selected situations, is a useful tool to optimize the angiographic result of stent implantation.
More Related Videos
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Hemodialysis I: Introduction