Purpose:
To compare long-term fluctuation of blue-on-yellow automated perimetry with white-on-white automated perimetry in normal subjects.
Methods:
White-on-white and blue-on-yellow automated perimetry were performed on a Humphrey Visual Field Analyzer and an Octopus perimeter, both modified for blue-on-yellow perimetry. The study sample consisted of 31 eyes of 31 normal subjects for the Humphrey perimeter and 33 eyes of 33 normal subjects for the Octopus perimeter. After one practice session, each subject completed four testing sessions over a period of 2 to 8 weeks, each separated by at least 1 day. Each testing session consisted of both white-on-white and blue-on-yellow perimetry performed on one eye; the order of the tests was alternated for successive sessions. Long-term fluctuation (expressed as statistical variance) was calculated for each test location. Intersubject variability (expressed as statistical variance) across all subjects was determined for each test location.
Results:
On the Humphrey perimeter, the long term fluctuation for blue-on-yellow perimetry (4.07 +/- 3.07 dB2) was significantly greater than that for white-on-white perimetry (1.97 +/- 0.99 dB2; P < .001). Long-term fluctuation increased as a function of eccentricity for both blue-on-yellow and white-on-white perimetry. Short-term fluctuation was significantly greater for blue-on-yellow (0.46 +/- 0.25 dB) than that for white-on-white perimetry (0.29 +/- 0.19 dB; P < .02). Finally, the intersubject variability was significantly greater in blue-on-yellow (13.2 +/- 2.8 dB2) than it was in white-on-white perimetry (4.25 +/- 1.13 dB2; P < .001). Similar results were found with the Octopus perimeter.
Conclusions:
Long-term fluctuation and short-term fluctuation of blue-on-yellow perimetry are greater than those of white-on-white perimetry in normal subjects. The increased long-term fluctuation requires appropriate statistical approaches when evaluating serial change of blue-on-yellow perimetry.
Related Concept Videos
Color Vision
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Testing a Claim about Mean: Unknown Population SD
Estimating a population mean requires the samples to be approximately normally distributed. The data should be collected from the randomly selected samples having no sampling bias. There is no specific requirement for sample size. But if the sample size is less than 30, and we don't know the population standard deviation, a different approach is used; instead...