Reactive hyperemic response of the brachial artery: comparison of proximal and distal occlusion

R Saouaf1, S Arora, P Smakowski

  • 1Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Mass., USA.

Academic Radiology
|August 14, 1998
PubMed
Abstract

Related Concept Videos

Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure01:21

Sites for measuring blood pressure

Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Arteries of the Upper Limbs01:12

Arteries of the Upper Limbs

The subclavian artery transitions into the axillary artery as it exits the chest and enters the axillary region. This artery is critical for supplying blood to the shoulder area, including the head of the humerus, through the humeral circumflex arteries. As the vessel continues into the upper arm or brachium, it becomes the brachial artery. This artery plays a key role in vascularizing the brachial region and bifurcates at the elbow into several branches. These branches include the deep...