Purpose:
The purpose of this study was to determine the test-retest reliability of an isometric handgrip exercise protocol designed to evaluate heart rate and arterial pressure responses in individuals with multiple sclerosis (MS). METHODS Three males and eleven females, aged 24 through 51, performed isometric handgrip contractions at 30% of maximal voluntary contraction (MVC) to the point of fatigue (defined as inability to maintain the target force for three consecutive seconds). During this exercise, rate of perceived exertion (RPE) was recorded every 30 s. Heart rate and beat-to-beat systolic, diastolic, and mean arterial pressures were recorded continuously throughout the duration of exercise. Surface EMG was monitored continuously via loudspeaker to provide feedback on extraneous muscular activity. Each subject performed three trials. A repeated measures ANOVA was used to calculate interclass reliability estimates for each dependent variable.
Results:
Reliability estimates for MVC and time to fatigue were 0.98 and 0.84, respectively. Reliability estimates for the following dependent variables at the point of fatigue were: RPE, 0.90; delta HR, 0.97; delta systolic pressure, 0.92; delta diastolic pressure, 0.87; and delta MAP, 0.88.
Conclusions:
We conclude that this isometric handgrip protocol is a reliable method for evaluating heart rate and blood pressure responses in MS patient.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...