Effects of PEEP on systemic venous capacitance
B Lambermont1, O Detry, V D'Orio
1Experimental Hemodynamics Laboratory (HemoLiège), University of Liège, Belgium.
Positive end-expiratory pressure (PEEP) reduces venous compliance and increases peripheral blood pooling. This impedes venous return, decreasing cardiac output due to reduced preload.
Area of Science:
- Physiology
- Cardiovascular System
- Respiratory System
Background:
- Positive end-expiratory pressure (PEEP) is used in mechanical ventilation.
- Its effects on peripheral venous capacitance and central hemodynamics require further elucidation.
Purpose of the Study:
- To determine the effects of PEEP on peripheral venous capacitance.
- To relate these changes to central hemodynamic disturbances.
Main Methods:
- Studied venous volume-pressure (V/P) relationships in 6 anesthetized pigs.
- Assessed systemic venous compliance and unstressed volume.
- Measured cardiac volumes and blood volume partitioning using thermo-dye dilution techniques.
Main Results:
- PEEP application (15 cm H2O) reduced venous compliance by 48%.
- Unstressed volume increased by 25%, with peripheral blood pooling rising from 63% to 74%.
- Left heart and right ventricular end-diastolic volumes decreased by 8% and 44%, respectively.
Conclusions:
- Increased venous unstressed volume and reduced compliance due to PEEP impede venous return.
- This leads to decreased cardiac output secondary to reduced preload.
Related Concept Videos
Veins as Blood Reservoirs
Measurement of Blood Pressure
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Overview of Systemic Veins
The coronary sinus, the heart's principal vein, resides in the coronary sulcus on the heart's posterior aspect. This broad venous channel receives nearly all venous blood from the myocardium, the heart muscle. It is fed by three primary veins: the great cardiac vein, the middle...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies