Evidence for a central origin of the low-frequency oscillation in RR-interval variability
R L Cooley1, N Montano, C Cogliati
1Department of Internal Medicine, College of Medicine, University of Iowa, Iowa City 52242, USA.
Congestive heart failure (CHF) patients regain normal heart rate variability (HRV) low-frequency oscillations after left ventricular assist device (LVAD) implantation. This restoration suggests a fundamental property of autonomic outflow, independent of blood pressure and baroreflex.
Area of Science:
- Cardiovascular Physiology
- Autonomic Nervous System Function
- Medical Device Technology
Background:
- Short-term variability in RR interval and blood pressure exhibits low (LF) and high (HF) frequency oscillations.
- The arterial baroreflex is considered the primary driver of the LF component of RR variability.
- Severe congestive heart failure (CHF) is associated with diminished or absent LF oscillations in RR variability.
Observation:
- Spectral analysis of RR interval, blood pressure, and respiration was performed on two CHF patients before and after left ventricular assist device (LVAD) implantation.
- LF components of RR interval and blood pressure variability were absent in both CHF patients pre-LVAD.
- Post-LVAD implantation, RR interval spectral analysis revealed a restored, predominant LF oscillation in the native hearts, notably absent in the blood pressure profile.
Findings:
- The LF oscillation in the native heart's RR interval, absent in CHF, is restored during total circulatory support with an LVAD.
- This restored LF oscillation occurs without concurrent LF oscillations in blood pressure, suggesting it's independent of baroreflex mechanisms.
- The absence of LF oscillation in CHF is functional, reversible by LVAD circulation.
Implications:
- The LF oscillation in RR interval appears to be a fundamental property of central autonomic outflow.
- LVAD support can restore autonomic nervous system function related to heart rate variability in CHF patients.
- This study provides insights into the pathophysiology of autonomic dysfunction in heart failure and the potential of mechanical circulatory support to ameliorate it.
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Frequency Region: X–H Stretching
IR Frequency Region: Fingerprint Region
The...
RLC Circuit as a Damped Oscillator
Consider a series RLC circuit. Here, the presence of resistance in the circuit leads to energy loss due to joule heating in the resistance. Therefore, the total electromagnetic energy in the circuit is no longer constant and decreases with time. Since the magnitude of charge, current, and potential difference continuously decreases, their oscillations are said to be damped. This is...
Series RLC Circuit without Source
Characteristics of Series Resonant Circuit