A proposal for a transfer standard for validating pulse oximeter sensors

C S Ho1, S C Lin

  • 1HFZ-450, Rockville, MD 20850, USA.

Biomedical Sciences Instrumentation
|January 1, 1997
PubMed
Summary

A novel ring-shaped pulse oximeter (SpO2) sensor transfer standard allows direct comparison of two SpO2 sensors on the same digit. This method overcomes interference issues, improving biosensor validation accuracy for SpO2 monitoring.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Performance of TB Antigen-Based Skin Tests Amongst Healthcare Workers-Sevagram, India, 2023-2024.

Open forum infectious diseases·2026
Same author

Long-term follow-up of persons diagnosed with multidrug-resistant TB in Chennai, India, 2013-2020.

The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease·2024
Same author

Development of a high-resolution typing method for SLA-3, swine MHC class I antigen 3.

Animal genetics·2021
Same author

Identification of a novel HLA-A*02 allele, HLA-A*02:01:01:32, in a deceased Caucasoid donor.

HLA·2018
Same author

Paradox of serial interferon-gamma release assays: variability width more important than specificity size.

The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease·2018
Same author

Intraspinal schwannoma and neurogenic bladder.

Annals of the Royal College of Surgeons of England·2018

Area of Science:

  • Biomedical Engineering
  • Medical Device Technology
  • Sensor Validation

Background:

  • Comparative assessment is crucial for biosensor validation.
  • Current adult pulse oximeter (SpO2) sensors interfere when placed on the same digit, necessitating placement on different digits with potentially varying SpO2 levels.

Purpose of the Study:

  • To propose a novel ring-shaped SpO2 sensor transfer standard for direct, comparative validation of SpO2 sensors on the same digit.
  • To address the interference issue in simultaneous SpO2 sensor placement.

Main Methods:

  • Development of a ring-shaped SpO2 sensor transfer standard.
  • Utilizing rapid sensor gating to measure the slowly varying SpO2 signal on the same digit.
  • Implementing a "switch over" trial design for direct comparison of two SpO2 sensors.
  • Discussion of hardware, software, and statistical analysis requirements.

Main Results:

  • The proposed transfer standard enables simultaneous measurement on the same digit, mitigating SpO2 level discrepancies between digits.
  • The "switch over" design facilitates direct comparison, enhancing validation accuracy.
  • The methodology addresses the interference problem inherent in current SpO2 sensor validation.

Conclusions:

  • The ring-shaped SpO2 sensor transfer standard offers a viable solution for accurate biosensor validation.
  • This approach improves the reliability of SpO2 monitoring by enabling direct comparison of sensors.
  • The proposed method enhances the precision of SpO2 measurement validation through a "switch over" design.