Related Experiment Video
Updated: Jul 29, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
A single scale for comparing dose-intensity of all chemotherapy regimens in breast cancer: summation dose-intensity
W Hryniuk1, E Frei, F A Wright
1Department of Medicine, University of California at San Diego Cancer Center, University of California at San Diego, La Jolla, USA.
Purpose:
To construct a single scale for comparing the dose-intensity of all chemotherapy regimens in breast cancer.
Materials And Methods:
First-line single-agent trials in metastatic disease were reviewed. The unit dose-intensity (UDI) that was required to produce a 30% complete response plus partial response (CR + PR) rate was determined for each drug. Randomized trials were then analyzed that prospectively tested dose-intensity. The dose-intensities of the drugs in each arm were expressed as fractions of their UDIs and added together. This yielded each arm's summation dose-intensity (SDI), which was then correlated with treatment outcomes.
Results:
In the single-agent trials, dose-response relationships were linear when the studies covered a range of dose-intensities. In the randomized trials that tested dose-intensity in metastatic disease, response rates and median survival correlated linearly with the SDIs of the treatment arms. An increment of one SDI unit increased CR + PR rate by approximately 30%, CR rate by 10%, and median survival by 3.75 months. Metastatic disease trials were negative if the difference between the arms was less than 0.54 SDI units. Adjuvant trials that tested a dose-intensity difference of less than 0.65 SDI units were also negative.
Conclusion:
A single-agent dose-response database can be derived from historic literature that enables comparison of the dose-intensity of all combination regimens on one scale. The dose-intensity increase required to improve outcome can then be identified in earlier trials that tested that variable. SDI methodology should be tested prospectively in contemporary patients, and may be useful in guiding dosage increases beyond the conventional range.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Dosage Regimens: Designs and Approaches
Dosage Regimen: Multiple Oral Dosage
Dosage Regimen: Individualization
Dosage Regimen Designs: Nomograms and Tabulations
Dose Response Curve: Conventional Versus Nonmonotonic