Related Experiment Video
Updated: Aug 5, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 30, 2011
Carbon monoxide and hospital admissions for congestive heart failure: evidence of an increased effect at low
1Department of Family Medicine and Community Health, Tufts University School of Medicine, Boston, MA 02111 USA.
Abstract:
The combined effects of carbon monoxide and low temperature on daily variation in hospital admissions for congestive heart failure (CHF) were examined for a 4-year period in Chicago, Illinois. Medicare hospital admissions for CHF were analyzed as a function of the maximum hourly temperature, maximum hourly levels of carbon monoxide (CO), and other criteria pollutants in Chicago for each day of the 4-year period (1986-1989). The regression analyses for the time series were conducted using single and multipollutant models with interaction terms and adjustments for weather, weekly cycles, seasonal effects, and secular trend. The data were also grouped into three temperature ranges, <40 degrees, 40 degrees-75 degrees, and >75 degrees F, and the relationship between CO and CHF admissions was evaluated for each range. For the 4-year time series, the CO level was positively associated with hospital admissions for CHF in the single pollutant and multipollutant models after adjustment for seasonal effects and weather pattern. The relative risks of hospital admissions for CHF in Chicago associated with the 75th percentile of exposure to CO in the high, medium, and low temperature ranges were 1.02 [95% confidence interval (CI), 0.95-1.10], 1.09 (CI, 1.04-1.14), and 1.15 (CI, 1.09-1.22), respectively. In these data, the effect of CO on hospital admissions for CHF was temperature dependent, with the magnitude of the effect increasing with decreasing temperature. This synergy may help to explain the association between ambient CO and CHF admissions demonstrated in other studies.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Related Concept Videos
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History