Comparison of three computerized videokeratoscopy systems with keratometry

R C Moura1, B L Bowyer, S X Stevens

  • 1Federal University of Sao Paulo, Brazil.

Cornea
|October 2, 1998
PubMed
Summary

Computerized videokeratoscopy systems show reproducible results within each device. However, significant differences exist between systems, meaning their clinical data should not be interchanged.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Diverse mobilome of Dichotomius (Luederwaldtinia) schiffleri (Coleoptera: Scarabaeidae) reveals long-range horizontal transfer events of DNA transposons.

Molecular genetics and genomics : MGG·2020
Same author

Physical mapping of 18S and 5S rDNA loci and histone H3 gene in grasshopper species of the subfamily Gomphocerinae (Acrididae).

Genetics and molecular research : GMR·2015
Same author

Patellofentoral dysfunction and overuse syndromes.

Journal of back and musculoskeletal rehabilitation·2014
Same author

Heterochromatin, sex chromosomes and rRNA gene clusters in Coprophanaeus beetles (Coleoptera, Scarabaeidae).

Cytogenetic and genome research·2012
Same author

Cytogenetics of the darkling beetles Zophobas aff. confusus and Nyctobates gigas (Coleoptera, Tenebrionidae).

Genetics and molecular research : GMR·2012
Same author

Cytogenetic mapping of rRNAs and histone H3 genes in 14 species of Dichotomius (Coleoptera, Scarabaeidae, Scarabaeinae) beetles.

Cytogenetic and genome research·2011

Area of Science:

  • Ophthalmology
  • Biomedical Engineering
  • Optometry

Background:

  • Computerized videokeratoscopy is crucial for corneal topography analysis.
  • Evaluating the reproducibility and inter-system agreement of these devices is essential for clinical applications.

Purpose of the Study:

  • To compare the reproducibility of three commercial videokeratoscopy systems (EyeSys, TechnoMed C-Scan, PAR Corneal Topography System [CTS]) using normal eyes and calibrated objects.

Main Methods:

  • Three videokeratoscopy systems and a manual keratometer were used.
  • Calibration spheres and 20 eyes from 10 normal subjects underwent 10 serial examinations on each system.
  • Average keratometry (K) within the central 3.0 mm was compared between systems and with manual keratometry.

Related Experiment Videos

Main Results:

  • All videokeratoscopy systems demonstrated good correlation with each other and manual keratometry for calibration objects.
  • EyeSys showed the strongest correlation with manual keratometry (35%), followed by PAR-CTS (25%) and C-Scan (5%).
  • Significant differences (p < 0.05) were found between systems when analyzing clinical data, with average K differences <0.35 D.

Conclusions:

  • While individual videokeratoscopy systems provide reproducible measurements, significant inter-system variability exists.
  • Results from different topography systems should not be assumed to be interchangeable in clinical studies.