Related Experiment Video
Updated: Aug 12, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Levels of carbon dioxide in helmet systems used during orthopaedic operations
M H Rubman1, M G Siegel, A S Echt
1Cincinnati Sportsmedicine Research and Education Foundation and Deaconess Hospital, Ohio 45219, USA.
Abstract:
The use of isolation helmets has gained popularity as a method of possible protection of the operating-room personnel from diseases that can be transmitted during operative procedures. However, the use of these systems has been associated with a variety of symptoms, including fatigue, diaphoresis, nausea, headache, and irritability. These symptoms have often been attributed to the mental stress of the operative procedure or the physical discomfort of the helmet. As far as we know, no manufacturers include the measured levels of carbon dioxide or the rate of air exchange of their helmet system. A possible common cause of discomfort with helmet systems is the level of carbon dioxide to which the person wearing the device is exposed. We measured the levels of carbon dioxide in four helmet systems from three different manufacturers during light exercise designed to approximate the exertion during an orthopaedic operation. All but one unit failed to meet the exposure limits recommended by the National Institute for Occupational Safety and Health and the Occupational Safety and Health Administration regarding exposure to carbon dioxide. One unit, the Stackhouse Freedom Aire self-contained system, did meet these standards, but the levels of carbon dioxide in this helmet were more than 1000 per cent greater than the ambient levels in air (440 parts per million compared with 4939 parts per million). Isolation systems must be evaluated carefully not only for comfort but also for the physiological effects caused by exposure to elevated levels of carbon dioxide. Operating-room personnel who use such systems should be aware that many of the physical symptoms that they experience may be associated with elevated levels of carbon dioxide.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...