Summary
The mandibular coronoid process closely matches the orbital floor
Area of Science:
- Craniomaxillofacial surgery
- Orthopedic surgery
- Plastic surgery
Background:
- Orbital floor reconstruction is crucial for restoring facial anatomy and function.
- Identifying suitable autologous bone grafts is essential for successful orbital floor repair.
- The mandibular coronoid process presents a potential donor site for orbital floor reconstruction.
Observation:
- Anatomical comparison of 24 human skulls revealed a close contour and dimensional match between the orbital floor and the contralateral mandibular coronoid process.
- Clinical application in eight patients with orbital floor fractures demonstrated the feasibility of using the coronoid process as a graft.
- Grafts required minimal trimming, with no need for recontouring the lateral cortical surface.
Findings:
- The coronoid process serves as an excellent donor graft for orbital floor reconstruction.
- Postoperative outcomes in eight patients showed correct orbital floor contour without diplopia, enophthalmia, muscle entrapment, or infection.
- Transient trismus (1-2 weeks) was the only noted complication.
Implications:
- The mandibular coronoid process offers a readily available and anatomically suitable option for orbital floor reconstruction.
- This technique can improve functional and aesthetic outcomes for patients with orbital floor defects.