Related Experiment Video
Updated: Sep 3, 2026

A Simple Non-invasive Method for Temporary Knockdown of Upper Limb Proprioception
Published on: March 3, 2018
The N18 component of the median nerve SEP is not reduced by vibration
G M Manzano1, N Negrão, J A Nóbrega
1Department of Neurology, Escola Paulista de Medicina, UNIFESP, São Paulo, SP, Brazil.
Objective:
To study the interference of mechanical vibration of the palm of the hand on the median nerve short-latency SEP components.
Methods:
Electrically-elicited short-latency median nerve SEP were obtained before and during mechanical vibration (120 Hz) of the palm in two groups of normal individuals (6 in group I and 9 in group II). The amplitude of the different components was compared between the two conditions through non-parametric statistical tests.
Results:
A significant reduction in the amplitude of the N9, P13/14 and N20 components was detected, however no overall significant changes were detected for the N18 component.
Conclusions:
Vibration interference reduced all studied components except the N18, these findings are interpreted as supporting evidence for the proposed association between the N18 component and the inhibitory activities elicited in the dorsal column nuclei.
Related Concept Videos
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...
Spinal Nerves: Plexus I
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...