Related Experiment Video
Updated: Aug 4, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Comparison of results in two implantable defibrillators. Jewel 7219D Investigators
A Pacifico1, J W Johnson, M S Stanton
1Texas Arrhythmia Institute, Houston 77030, USA.
Abstract:
The Jewel 7219D was the first non-thoracotomy implantable cardioverter-defibrillator (ICD) with biphasic shock capability small enough to be placed in the prepectoral subcutaneous position. Size reduction of ICDs is desirable, but safety and efficacy of smaller devices must be demonstrated. Outcomes of patients treated with the Jewel 7219D defibrillator (n = 1,781) and with its precursor model PCD 7217B (n = 2,637) were compared. To use PCD patients (n = 2,637) as historical (n = 2,574) and concurrent controls (n = 63), statistical adjustments using the Cox proportional-hazards regression model were made. Jewel recipients (n = 1,781) treated in 106 US and 32 non-US centers exhibited similar characteristics including a mean age of 59 years, 78% men, ejection fraction of 34%, history of aborted sudden cardiac death in 41%, and coronary artery disease in 70%. Implantation was completed in 1,777 of 1,781 (99.9%) attempts and success with the first electrode configuration and polarity was 89.5%. Kaplan-Meier cumulative first-year survivals for cardiac and all-cause mortality were 98.5% and 93.3%. Complication-free first-year survival for Jewel implants in prepectoral subcutaneous (n = 582), subpectoral submuscular (n = 366), and abdominal (n = 449) positions did not differ (p > 0.05). First-year survival free of pocket-related complications exceeded 98% in all locations. Adjusted cardiac and all-cause first-year mortality, and efficacy in terminating spontaneous tachyarrhythmias did not differ between the 2 device groups. In conclusion, the safety and efficacy of Jewel model 7219D in the prepectoral subcutaneous position are at least equal to either those of Jewel models implanted in different positions or to those of the previously extensively characterized PCD 7217B.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Acute Coronary Syndrome III: Diagnostic Studies
Cardiopulmonary Resuscitation III: AED Use