Related Experiment Video
Updated: Aug 5, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Three-dimensional imaging and osteometry of adult human skulls using helical computed tomography
M Nagashima1, K Inoue, T Sasaki
1Department of Anatomy, Hokkaido University School of Medicine, Sapporo, Japan.
Abstract:
To make a digital image database of human craniology, we optimized the three-dimensional (3-D) images of 29 dried human skull specimens by helical computed tomography (CT). For the verification of the quantitative exactitude of these image data, we manually measured nine items of direct distances between standard anthropologic points on each skull and the corresponding distances projected on the CT monitor by specifying the respective points. The results obtained by the two methods of manual and CT measurements were compared and statistically analyzed. The CT measurements were so exact that the lower limit of correlation coefficients (95% of the confidence interval) between the two results was more than 0.8 in six items; i.e., maximal cranial length and breadth, minimal frontal breadth, bizygomatic breadth, distance between ectomolares and nasion-basion length. In contrast, the CT results were less well correlated with the manual measurements of three items; i.e., distance between bilateral mastoidales, total facial height, and nasal breadth. We concluded that the qualitative representation of 3-D CT images was adequate, although some quantitative data may be incorrect. The inaccuracy is suspected to be due to the difficulty in specifying the standard points on the CT images, and due to the differences in measurement procedures between the direct and projected distances.
More Related Videos
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...