Related Experiment Video
Updated: Jul 21, 2026

Recapitulation of an Ion Channel IV Curve Using Frequency Components
Published on: February 8, 2011
Theoretical limits on the threshold for the response of long cells to weak extremely low frequency electric fields
J C Weaver1, T E Vaughan, R K Adair
1Harvard-M.I.T. Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
Abstract:
Understanding exposure thresholds for the response of biological systems to extremely low frequency (ELF) electric and magnetic fields is a fundamental problem of long-standing interest. We consider a two-state model for voltage-gated channels in the membrane of an isolated elongated cell (Lcell = 1 mm; rcell = 25 micron) and use a previously described process of ionic and molecular flux rectification to set lower bounds for a threshold exposure. A key assumption is that it is the ability of weak physical fields to alter biochemistry that is limiting, not the ability of a small number of molecules to alter biological systems. Moreover, molecular shot noise, not thermal voltage noise, is the basis of threshold estimates. Models with and without stochastic resonance are used, with a long exposure time, texp = 10(4) s. We also determined the dependence of the threshold on the basal transport rate. By considering both spherical and elongated cells, we find that the lowest bound for the threshold is Emin approximately 9 x 10(-3) V m-1 (9 x 10(-5) V cm-1). Using a conservative value for the loop radius rloop = 0.3 m for induced current, the corresponding lower bound in the human body for a magnetic field exposure is Bmin approximately 6 x 10(-4) T (6 G). Unless large, organized, and electrically amplifying multicellular systems such as the ampullae of Lorenzini of elasmobranch fish are involved, these results strongly suggest that the biophysical mechanism of voltage-gated macromolecules in the membranes of cells can be ruled out as a basis of possible effects of weak ELF electric and magnetic fields in humans.
Related Concept Videos
The Resting Membrane Potential
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Resting Potential Decay
At rest, the K+ is the main ion that moves across the membrane through...
Induced Electric Fields: Applications
Theory of Strong Electrolytes
Applications of EMF Measurements