Correlation integral of blood pressure as a marker for exercise intensities
C D Wagner1, H M Stauss, P B Persson
1Department of Physiology, Humboldt University of Berlin, D-10117 Berlin, Germany.
Abstract:
The purpose of this study was to test the hypothesis that the correlation integral technique detects altered regulation of cardiovascular function during graded treadmill exercise. Arterial blood pressure (BP) was measured via telemetry before and during graded treadmill exercise in Sprague-Dawley rats. During treadmill running at mild, moderate, and heavy exercise intensities, the slope of the correlation integrals (SCI) continuously increased from 5.45 +/- 0.17 to 7.12 +/- 0.18, 7.92 +/- 0.23, and 8.40 +/- 0.23, respectively. However, corresponding changes in pulse interval, blood pressure, and systolic blood pressure with increasing workload were not consistently observed. Low-frequency, midfrequency, and high-frequency powers of BP were not different between adjacent exercise grades; only the low-frequency component of pulse interval was different between resting state and mild exercise, and BP variance was significantly different between mild and moderate grades. Comparison of the SCI values with those obtained from surrogate data sets suggests that these differences originate mainly from nonlinear components in the cardiovascular control system. These findings support the hypothesis that SCI detects alterations in cardiovascular regulation associated with graded exercise. Furthermore, SCI may be superior to linear techniques in detecting altered regulation with changing exercise intensities.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.