A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Low pulse oximeter-measured hemoglobin oxygen saturations with hemoglobin Cheverly
R J Hohl1, A R Sherburne, J E Feeley
1Department of Internal Medicine, The University of Iowa, Iowa City 52242, USA. raymond-hohl@uiowa.edu
Abstract:
Unexpectedly low hemoglobin oxygen saturation as determined by pulse-oximeter analysis was observed in a patient who underwent an elective surgical procedure. Specific hemoglobin derivatives such as carboxyhemoglobin, methemoglobin, and reduced hemoglobin that have been described to lower pulse-oximetry determination of oxygenation were not detected. Absorbance spectra revealed the patient's hemoglobin to be different than that obtained from two normal volunteers. High-pressure liquid chromatographic analysis of the hemoglobin showed an unknown band that comprised 15% of the patient's hemoglobin. DNA sequence analysis showed a point mutation in the second nucleotide of the 45th codon of the beta-globin chain. This mutation encodes for an abnormal beta-chain (beta-45 Phe-->Ser) that has been described as hemoglobin Cheverly. Hemoglobin Cheverly is an unstable hemoglobin that has a similar mutation as the beta-42 Phe-->Ser mutation seen in hemoglobin Hammersmith. Hemoglobin Hammersmith and another unstable hemoglobin, hemoglobin Köln, have previously been described to have unexpectedly low pulse-oximeter-determined oxyhemoglobin levels. That we find hemoglobin Cheverly to result in a similar phenomenon suggests that pulse-oximeter monitoring of oxygenation status may not be appropriate for the unstable hemoglobins. Low pulse-oximeter oxygenation determinations for these hemoglobins do not appear to predict clinical hypoxemia.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...